Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 166
Filter
1.
Arq. bras. oftalmol ; 87(4): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520230

ABSTRACT

ABSTRACT Purpose: To evaluate the influence of atmospheric pressure changes on the behavior of intraocular pressure of healthy military individuals-students and instructors of the National Navy's Diving & Rescue School at the "ARC BOLÍVAR" naval base-during a simulated immersion in the hyperbaric chamber of the Naval Hospital of Cartagena. Methods: A descriptive exploratory study was performed. The intraocular pressure was measured at different atmospheric pressures during 60-min sessions in the hyperbaric chamber while breathing compressed air. The maximum simulated depth was 60 feet. Participants were students and instructors of the Naval Base's Diving and Rescue Department. Results: A total of 48 eyes from 24 divers were studied, of which 22 (91.7%) were male. The mean age of the participants was 30.6 (SD=5.5) years, ranging from 23 to 40. No participant had a history of glaucoma or ocular hypertension. The mean base intraocular pressure at sea level was 14 mmHg, which decreased to 13.1 mmHg (decreased by 1.2 mmHg) at 60 feet deep (p=0.0012). However, during the safety stop at 30 feet, the mean IOP kept decreasing until reaching 11.9 mmHg (p<0.001). By the end of the session, the mean intraocular pressure reached 13.1 mmHg, which is inferior and statistically significant when compared with the intraocular pressure base mean (p=0.012). Conclusions: In healthy individuals, the intraocular pressure decreases when reaching a depth of 60 feet (2.8 absolute atmosphere pressure) and it decreases even more during ascension at 30 feet. Measurements at both points were significantly different when compared with base intraocular pressure. The final intraocular pressure was lower than the baseline intraocular pressure, suggesting a residual and prolonged effect of the atmospheric pressure on intraocular pressure.


RESUMO Objetivo: Avaliar a influência das alterações da pressão atmosférica no comportamento da pressão intraocular de indivíduos militares saudáveis-alunos e instrutores da Escola de Mergulho e Resgate da Marinha Nacional na base naval "ARC BOLÍVAR"-durante uma imersão simulada na câmara hiperbárica do Hospital da Marinha de Cartagena. Métodos: Realizamos um estudo exploratório descritivo. A pressão intraocular foi medida em diferentes pressões atmosféricas durante sessões de 60 minutos na câmara hiperbárica respirando ar comprimido. A profundidade máxima simulada foi de 60 pés. Os participantes eram alunos e instrutores do Departamento de Mergulho e Resgate da Base Naval. Resultados: Quarenta e oito olhos de 24 mergulhadores foram estudados. Vinte e dois participantes (91,7%) eram do sexo masculino. A média de idade dos participantes foi de 30,6 (DP=5,5) anos, variando de 23 a 40. Nenhum participante tinha histórico de glaucoma ou hipertensão ocular. A média de base da pressão intraocular ao nível do mar foi de 14 mmHg, diminuindo para 13,1 mmHg (queda de 1,2 mmHg) a 60 pés de profundidade (p=0,0012). Entretanto, durante a parada de segurança a 30 pés, a pressão intraocular média continuou diminuindo até atingir 11,9 mmHg (p<0,001). Ao final da sessão, a pressão intraocular média atingiu 13,1 mmHg, valor inferior e estatisticamente significativo quando comparada à média de base da pressão intraocular (p=0,012). Conclusões: Em indivíduos saudáveis, a pressão intraocular diminui ao atingir uma profundidade de 60 pés (2,8 de pressão atmosférica absoluta) e diminui ainda mais durante a ascensão a 30 pés. As medidas em ambos os pontos foram significativamente diferentes quando comparadas à pressão intraocular de base. A pressão intraocular final foi menor do que a pressão intraocular de base, sugerindo um efeito residual e prolongado da pressão atmosférica sobre a pressão intraocular.

2.
Arq. bras. oftalmol ; 87(6): e2022, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1520246

ABSTRACT

ABSTRACT Purpose: To evaluate using optical coherence tomography angiography the macular and optic nerve head blood flow in pediatric patients with epilepsy treated with levetiracetam for at least 12 months. Methods: This study included 33 pediatric patients with epilepsy and 30 sex- and age-matched healthy volunteer children were included in the study. Optical coherence tomography angiography was used to evaluate the optic nerve head and macular perfusion changes. The mean ocular perfusion pressures were also calculated. Patients who were using multiple antiepileptic drugs or had a prior history of using different drugs were excluded. Results: The choriocapillaris flow area was significantly lower in the Study Group than in the Control Group (p=0.006). However, the foveal avascular zone and vessel densities of the macula in the superficial capillary plexus, deep capillary plexus, and optic nerve head of the study group were not significantly different from those of the control group (p>0.05). Moreover, no significant difference in means of mean ocular perfusion pressure was found between the two groups (p=0.211). No obvious correlation was found between treatment duration and optical coherence tomography angiography parameters or mean ocular perfusion pressure. Conclusion: Choroidal perfusion was reduced in children taking levetiracetam compared with that in the control group, whereas retinal perfusion was not affected in this optical coherence tomography angiography study.


RESUMO Objetivo: Avaliar através de angiotomografia de coerência óptica o fluxo sanguíneo macular e da cabeça do nervo óptico em pacientes pediátricos com epilepsia tratados com levetiracetam por pelo menos 12 meses. Método: Trinta e três pacientes pediátricos com epilepsia e 30 crianças voluntárias saudáveis pareadas por sexo e idade foram incluídos no estudo. A angiotomografia de coerência óptica foi utilizada para avaliar as alterações da perfusão da cabeça do nervo óptico e da macular. As médias das pressões de perfusão ocular também foram calculadas. Pacientes em uso de múltiplas drogas antiepilépticas ou com história prévia de uso de diferentes drogas foram excluídos do estudo. Resultado: A área do fluxo coriocapilar foi significativamente menor no Grupo Estudo do que no Grupo Controle (p=0,006). Entretanto, a zona avascular foveal e as densidades vasculares no plexo capilar superficial e profundo da região macular e na cabeça do nervo óptico não foram significativamente diferentes daquelas de olhos saudáveis (p>0,05). Também não houve diferença significativa entre os dois grupos em relação às médias da pressão de perfusão ocular (p=0,211). Nenhuma correlação aparente foi encontrada entre a duração do tratamento e os parâmetros da angiotomografia de coerência óptica ou a média da pressão de perfusão ocular. Conclusão: Em crianças usando levetiracetam, a perfusão coroidal mostrou-se reduzida em comparação ao grupo controle, enquanto a perfusão retiniana não foi afetada neste estudo com angiotomografia de coerência óptica.

3.
Arq. bras. oftalmol ; 87(1): e2021, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527807

ABSTRACT

ABSTRACT Purpose: Only a few trials have compared the intraocular pressure-lowering effects of prostaglandin analogs to carbonic anhydrase inhibitor plus beta-blocker fixed-dose combination therapy in patients with pseudoexfoliative glaucoma. Furthermore, the influence of the glaucoma stage on the intraocular pressure-lowering effects of these drug types has not been studied. The purpose of this study was to compare the IOP-lowering efficacy of latanoprost, a prostaglandin analog versus dorzolamide/timolol fixed combination, a carbonic anhydrase inhibitor plus beta-blocker fixed-dose combination therapy, in patients with pseudoexfoliative glaucoma based on glaucoma stage. Methods: The data of 32 eyes (32 patients) diagnosed with uniocular pseudoexfoliative glaucoma and treated with topical latanoprost (Group 1) or dorzolamide/timolol fixed combination (Group 2) were retrospectively assessed. The groups were subdivided into early and moderate-advanced stages. Patients' demographics, baseline intraocular pressure, final intraocular pressure, and intraocular pressure difference (the difference between the baseline and final intraocular pressure) were determined from medical records and compared between groups and according to glaucoma stage. Results: The mean drug use duration was 17.7 ± 13.5 months. No significant differences in mean baseline intraocular pressure, mean final intraocular pressure and mean intraocular pressure difference between Groups 1 and 2. In Group 2, the mean intraocular pressure difference was significantly greater in patients with early versus moderate-advanced stage glaucoma (p=0.015). The difference, however, was not detected in Group 1. The mean intraocular pressure difference in early-stage glaucoma was significantly greater in Group 2 versus 1 (p=0.033). Conclusions: Latanoprost and dorzolamide/timolol fixed combination are effective treatments for newly diagnosed pseudoexfoliative glaucoma. In early-stage pseudoexfoliative glaucoma, greater intraocular pressure reduction was noted with dorzolamide/timolol fixed combination than with latanoprost; thus, dorzolamide/timolol fixed combination should be considered when a significant decrease in intraocular pressure is desired in early-stage glaucoma.


RESUMO Objetivo: Estudos limitados examinaram os efeitos de redução de pressão intraocular de análogos de prostaglandina versus inibidor de anidrase carbônica mais terapia de combinação de dose fixa beta-bloqueador em pacientes com glaucoma pseudoesfoliativo. Além disso, a influência do estágio de glaucoma nos efeitos de redução da pressão intraocular desses tipos de drogas não foi avaliada. Este estudo teve como objetivo comparar a eficácia de redução do IOP do latanoprosta, uma combinação fixa análoga de prostaglandina versus dorzolamida/timolol, um inibidor de anidrase carbônica mais terapia de combinação de dose fixa beta-bloqueador, em pacientes com glaucoma pseudoesfoliativo de acordo com o estágio de glaucoma. Métodos: Os dados de 32 olhos (32 pacientes) diagnosticados com glaucoma pseudoesfoliativo monocular e tratados com latanoprosta tópica (Grupo 1) ou combinação fixa de dorzolamida/timolol (Grupo 2) foram avaliados retrospectivamente. Os grupos foram subdivididos em estágios inicial e moderado-avançado. A demografia dos pacientes, a pressão intraocular da linha de base, a pressão intraocular final e a diferença de pressão intraocular (a diferença entre a pressão intraocular da linha de base e a pressão intraocular final) foram determinadas a partir dos prontuários médicos e comparadas entre os dois grupos e de acordo com o estágio de glaucoma. Resultados: A duração média do uso de drogas foi de 17,7 ± 13,5 meses. Nenhuma diferença significativa foi observada entre os grupos 1 e 2 para a média da pressão intraocularda linha de base, média da pressão intraocular final e média da diferença da pressão intraocular. No Grupo 2, a média da diferença da pressão intraocular foi significativamente maior em pacientes com glaucoma de estágio precoce versus moderado-avançado (p=0,015). No entanto, essa diferença não foi observada no Grupo 1. A média da diferença da pressão intraocular em glaucoma de estágio inicial foi significativamente maior no Grupo 2 versus 1 (p=0,033). Conclusões: Terapias com Latanoprosta e dorzolamida/timolol são tratamentos eficazes para glaucoma pseudoesfoliativo recém-diagnosticado. Observou-se em glaucoma pseudoesfoliativo de estágio inicial, uma maior redução da pressão intraocular com combinação fixa de dorzolamida/timolol do que com latanoprosta; assim, a combinação fixa de dorzolamida/timolol deve ser considerada quando uma diminuição significativa da pressão intraocular é almejada em glaucoma de estágio inicial.

4.
Arq. bras. oftalmol ; 87(1): e2021, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527816

ABSTRACT

ABSTRACT Purpose: To evaluate the effect of tobacco smoking on trabeculectomy outcomes. Methods: Charts of patients with glaucoma who underwent trabeculectomy performed by a single surgeon between 2007 and 2016 were retrospectively reviewed. Charts were screened for a documented history of smoking status before surgery. Demographic and clinical preoperative variables were recorded. Based on smoking history, subjects were divided into two groups: smokers and nonsmokers. Any bleb-related interventions (e.g., 5-flourouracil injections ± laser suture lysis) or bleb revision performed during the postoperative period were noted. Success was defined as an intraocular pressure >5 mmHg and <21 mm Hg without (complete success) or with (qualified success) the use of ocular hypotensive medications. Failure was identified as a violation of the criteria mentioned above. Results: A total of 98 eyes from 83 subjects were included. The mean age of the subjects was 70.7 ± 11.09 years, and 53% (44/83) were female. The most common diagnosis was primary open-angle glaucoma in 47 cases (47.9%). The smokers Group included 30 eyes from 30 subjects. When compared with nonsmokers, smokers had a significantly worse preoperative best-corrected visual acuity (p=0.038), greater central corneal thickness (p=0.047), and higher preoperative intraocular pressure (p=0.011). The success rate of trabeculectomy surgery at 1 year was 56.7% in the smokers Group compared with 79.4% in the Group nonsmokers (p=0.020). Smoking presented an odds ratio for failure of 2.95 (95% confidence interval, 1.6-7.84). Conclusion: Smokers demonstrated a significantly lower success rate 1 year after trabeculectomy compared with nonsmokers and a higher requirement for bleb-related interventions.


RESUMO Objetivo: Avaliar o efeito do tabagismo nos desfechos da trabeculectomia. Métodos: Uma revisão retrospectiva do gráfico de pacientes com glaucoma submetidos à trabeculectomia foi realizada por um único cirurgião entre 2007 e 2016. Os gráficos foram examinados para uma história documentada de condição de fumante antes da cirurgia. Variáveis pré-operatórias clínicas e demográficas e clínicas foram registradas. Os pacientes foram divididos em dois grupos de acordo com sua história de tabagismo em fumantes e não fumantes. Quaisquer Intervenções relacionadas à bolha, por exemplo, injeções de 5-fluorouracil + lise de sutura com laser, ou revisão da bolha realizada durante o período pós-operatório foram observadas. O sucesso foi definido como pressão intraocular > 5 mmHg e < 21 mm Hg sem (sucesso completo) ou com (sucesso qualificado) medicamentos hipotensores oculares. A falha foi identificada como violação dos critérios mencionados acima. Resultados: O estudo incluiu 98 olhos de 83 pacientes com idade média de 70,7 ± 11,09 anos, sendo 53% (44/83) dos pacientes do sexo feminino. O diagnóstico mais comum foi o glaucoma de ângulo aberto primário com 47 casos (47,9%). O Grupo de fumantes incluiu 30 olhos de 30 pacientes. Os fumantes, quando comparados aos não fumantes, apresentaram uma melhor acuidade visual pré-operatória significativamente pior (p=0,038), maior espessura central da córnea (p=0,047) e maior pressão intraocular pré-operatória (p=0,011). A taxa de sucesso de um ano para a cirurgia de trabeculectomia foi de 56,7% no Grupo de fumantes contra 79,4% no Grupo de não fumantes (p=0,020). O tabagismo apresentou razão de chances para falha de 2,95 95% de IC (1,6-7,84). Conclusão: Os fumantes demonstraram uma taxa de sucesso significativamente menor em um ano após a trabeculectomia em comparação com os não fumantes e uma maior necessidade de intervenções relacionadas à bolha.

5.
Arq. bras. oftalmol ; 86(4): 337-344, July-Sep. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1447372

ABSTRACT

ABSTRACT Purpose: This study aimed to compare the clinical outcomes following deep anterior lamellar keratoplasty and penetrating keratoplasty in contralateral eyes of the same patients. Methods: In this retrospective, comparative case series, clinical outcome data included best-corrected visual acuity, refractive spherical equivalent, refractive astigmatism, endothelial cell density, endothelial cell loss, central corneal thickness, and intraocular pressure, which were evaluated at 6, 12, 24, and 36 months after deep anterior lamellar keratoplasty and penetrating keratoplasty. Additionally, complications were assessed. Results: Fifty-two eyes (26 patients) were included, of which 19 patients had keratoconus, 6 had stromal dystrophy, and 1 had post-laser-assisted in situ keratomileusis ectasia. The mean follow-up was 44.1 ± 10.5 months in the deep anterior lamellar keratoplasty Group and 47.9 ± 11.9 months in the penetrating keratoplasty Group. No significant differences were observed in the mean best-corrected visual acuity, refractive spherical equivalent, refractive astigmatism, and central corneal thickness between the deep anterior lamellar keratoplasty and penetrating keratoplasty Groups during follow-up. The endothelial cell density was significantly higher in the deep anterior lamellar keratoplasty Group than in the penetrating keratoplasty Group at 24 and 36 months postoperatively (p=0.022 and 0.013, respectively). Endothelial cell loss was significantly lower in the deep anterior lamellar keratoplasty Group than in the penetrating keratoplasty Group at 24 and 36 months postoperatively (p=0.025 and 0.001, respectively). Intraocular pressure was significantly lower in the deep anterior lamellar keratoplasty Group than in the penetrating keratoplasty Grroup at 6 months postoperatively (p=0.015). Microperforation occurred in 4 eyes (15%) during deep anterior lamellar keratoplasty surgery; however, penetrating keratoplasty was not required. No endothelial rejection occurred in the penetrating keratoplasty Group during follow-up. Conclusions: Over the 3-year follow-up, endothelial cell loss and intraocular pressure in the deep anterior lamellar keratoplasty Group were significantly lower than those in the penetrating keratoplasty Group, while visual and refractive results were similar.


RESUMO Objetivo: Este estudo teve como objetivo comparar os resultados clínicos após ceratoplastia lamelar anterior profunda e ceratoplastia penetrante nos olhos contralaterais dos mesmos pacientes. Métodos: Nesta série de casos comparativa e retrospectiva, avaliaram-se os seguintes dados de resultados clínicos: melhor acuidade visual corrigida, equivalente esférico refrativo, astigmatismo refrativo, densidade de células endoteliais, perda de células endoteliais, espessura central da córnea e pressão intraocular. Esses dados foram avaliados aos 6, 12, 24 e 36 meses após ceratoplastia lamelar anterior profunda e ceratoplastia penetrante. Também foram avaliadas as complicações. Resultados: Foram incluídos 52 olhos (26 pacientes), sendo que 19 pacientes apresentavam ceratocone, 6 apresentavam distrofia estromal e 1 apresentava ectasia após ceratomileuse in situ assistida por laser. O tempo médio de acompanhamento foi de 44,1 ± 10,5 meses no grupo da ceratoplastia lamelar anterior profunda e 47,9 ± 11,9 meses no grupo da ceratoplastia penetrante. Nenhuma diferença significativa foi observada nas médias da melhor acuidade visual corrigida, equivalente esférico refrativo, astigmatismo refrativo e espessura central da córnea entre os grupos da ceratoplastia lamelar anterior profunda e da ceratoplastia penetrante durante o acompanhamento. A densidade de células endoteliais foi significativamente maior no grupo da ceratoplastia lamelar anterior profunda que no grupo da ceratoplastia penetrante aos 24 e 36 meses de pós-operatório (p=0,022 e 0,013, respectivamente). A perda de células endoteliais foi significativamente menor no grupo da ceratoplastia lamelar anterior profunda que no grupo da ceratoplastia penetrante aos 24 e 36 meses de pós-operatório (p=0,025 e 0,001, respectivamente). A pressão intraocular foi significativamente menor no grupo da ceratoplastia lamelar anterior profunda que no grupo da ceratoplastia penetrante aos 6 meses de pós-operatório (p=0,015). Ocorreu microperfuração em 4 olhos (15%) durante a cirurgia de ceratoplastia lamelar anterior profunda; entretanto, a ceratoplastia penetrante não foi necessária. Não ocorreu nenhuma rejeição endotelial no grupo da ceratoplastia penetrante durante o período de acompanhamento. Conclusões: Durante o acompanhamento de 3 anos, a perda de células endoteliais e a pressão intraocular foram significativamente menores no grupo da ceratoplastia lamelar anterior profunda que no grupo da ceratoplastia penetrante, mas os resultados visuais e refrativos foram semelhantes.

6.
Arq. bras. oftalmol ; 86(3): 217-222, May 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1439378

ABSTRACT

ABSTRACT Purpose: The nasal sector of the anterior chamber angle may present a higher density of collector channels, which may influence the results of angle surgeries. Considering the anatomical differences in the anterior chamber angle, we compared the results of the nasal and temporal 180° selective laser trabeculoplasty approaches for open-angle glaucoma. Methods: A retrospective chart review was conducted for patients with open-angle glaucoma (primary, pseudoexfoliation, and pigmentary) who underwent at least one 180° selective laser trabeculoplasty session between December 2016 and October 2018. The nasal (N1) or temporal (T1) sectors were chosen at the physician's discretion. Patients who did not experience decreased intraocular pressure between 3 and 6 months again underwent 180° selective laser trabeculoplasty in the opposite angle sector (T2 and N2). The main outcome measured was decrease in intraocular pressure at 6-month follow-up, after the last selective laser trabeculoplasty. A multivariable regression analysis was used to evaluate factors associated with decreased intraocular pressure after treatment. Results: The procedure was performed initially in 45 eyes (N1, 25; T1, 20 eyes) and repeated in the opposite anterior chamber angle sector in 19 eyes (N2, 11; T2, 8 eyes). Analysis of variance revealed that only the N1 approach presented a significant difference in the decrease in intraocular pressure as compared with the T1, N2, and T2 approaches (p=0.0014). The baseline intraocular pressure (p=0.021) and anterior chamber angle sector (N1; p=0.044) correlated with decreased intraocular pressure. Conclusion: Compared with the temporal approach, 180° selective laser trabeculoplasty performed initially in the nasal sector was associated with a more significant decrease in intraocular pressure. Considering the sectorial differences in the anterior chamber angle, further prospective trials are warranted to confirm our findings and provide more-efficient selective laser trabeculoplasty protocols.


RESUMO Objetivo: O setor nasal do ângulo da câmara anterior pode apresentar maior densidade de canais coletores, o que pode influenciar no resultado de cirurgias angulares. Considerando as diferenças anatômicas no ângulo da câmara anterior, comparamos os resultados das abordagens de trabeculoplastia seletiva a laser nasal e temporal de 180 graus no glaucoma de ângulo aberto. Métodos: Revisão retrospectiva de prontuários de pacientes com glaucoma de ângulo aberto (primária, pseudoexfoliação e pigmentar), que realizaram pelo menos uma sessão de trabeculoplastia seletiva a laser de 180 graus entre dezembro/2016 e outubro/2018. O setor nasal (N1) ou temporal (T1) foi escolhido a critério do médico. Os pacientes que não apresentaram diminuição da pressão intraocular (PIO) entre 3 e 6 meses foram retratados com trabeculoplastia seletiva a laser de 180 graus no setor de ângulo oposto (T2 e N2). O principal resultado medido foi a diminuição da pressão intraocular no 6º mês de acompanhamento após a última trabeculoplastia seletiva a laser. Uma análise de regressão multivariável avaliou os fatores associados à redução da pressão intraocular após o tratamento. Resultados: O procedimento foi realizado inicialmente em 45 olhos (N1=25, T1=20 olhos), e repetido no setor ângulo da câmara anterior oposto em 19 olhos (N2 = 11, T2 = 8 olhos). Os testes ANOVA mostraram que apenas a abordagem N1 apresentou diferença significativa na diminuição da pressão intraocular em relação a T1, N2 e T2 (p=0,0014). A pressão intraocular basal (p=0,021) e o setor ângulo da câmara anterior (N1; p=0,044) se correlacionaram com a diminuição da pressão intraocular. Conclusão: A trabeculoplastia seletiva a laser de 180 graus realizado inicialmente no setor nasal foi associado a uma diminuição mais significativa da pressão intraocular em comparação com a abordagem temporal. Considerando as diferenças setoriais no ângulo da câmara anterior, mais estudos prospectivos são necessários para confirmar nossos achados e fornecer protocolos para trabeculoplastia seletiva a laser mais eficientes.

7.
Arq. bras. oftalmol ; 86(3): 223-231, May 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1439379

ABSTRACT

ABSTRACT Purpose: To compare viscotrabeculotomy with anterior chamber irrigation to Ahmed glaucoma valve implantation for secondary glaucoma following silicone oil removal. Methods: A prospective study was conducted on 43 vitrectomized pseudophakic eyes with persistent glaucoma after silicone oil removal. Patients were randomized to either viscotrabeculotomy with anterior chamber irrigation or Ahmed glaucoma valve implantation. All patients were examined on day 1, week 1, and months 1, 3, 6, 9, 12, 18, and 24 postoperatively. Postoperative complications were noted. Success was defined as an intraocular pressure between 6 and 20 mmHg and with an intraocular pressure reduction of >30% compared with the preoperative intraocular pressure. Results: There were 22 eyes in the viscotrabeculotomy with anterior chamber irrigation and 21 eyes in the Ahmed glaucoma valve implantation group. The mean preoperative and postoperative intraocular pressure in the viscotrabeculotomy with anterior chamber irrigation and Ahmed glaucoma valve implantation groups were 35.5 ± 2.6 mmHg and 35.5 ± 2.4 mmHg and 16.9 ± 0.7 mmHg and 17.9 ± 0.9 mmHg respectively (p˂0.0001). There was a statistically significant intraocular pressure reduction at all follow-up time points compared to preoperative values (p˂0.0001) in both groups. The unqualified success rate in the viscotrabeculotomy with anterior chamber irrigation and Ahmed glaucoma valve implantation groups were 72.73% and 61.9%, respectively. A minimal self-limited hyphema was the most common complication. Conclusions: Both viscotrabeculotomy with anterior chamber irrigation and Ahmed glaucoma valve implantation are effective in lowering the intraocular pressure in glaucoma after silicone oil removal with viscotrabeculotomy with anterior chamber irrigation providing greater reduction, higher success rates, and minimal complications.


RESUMO Objetivo: Comparar a viscotrabeculotomia com irrigação da câmara anterior com o implante de válvula de glaucoma de Ahmed para glaucoma secundário após remoção de óleo de silicone. Métodos: Foi realizado um estudo prospectivo de 43 olhos pseudofácicos vitrectomizados com glaucoma persistente após a remoção de óleo de silicone. Os pacientes foram randomizados para viscotrabeculotomia com irrigação da câmara anterior ou implante de válvula de Ahmed. Todos os pacientes foram examinados no primeiro dia, na primeira semana e 1, 3, 6, 9, 12, 18 e 24 meses após a cirurgia. Observaram-se complicações pós-operatórias. O sucesso foi definido como uma pressão intraocular entre 6 e 20 mmHg e uma redução da pressão intraocular >30% em comparação com a pressão intraocular pré-operatória. Resultados: Foram designados 22 olhos para o grupo da viscotrabeculotomia com irrigação da câmara anterior e 21 olhos para o grupo do implante de válvula de Ahmed. A pressão intraocular média pré-operatória foi de 35,5 ± 2,6 mmHg para o grupo da viscotrabeculotomia com irrigação da câmara anterior e pós- e de 35,5 ± 2,4 mmHg no grupo do implante de válvula de Ahmed. e Os valores pós-ope­ratórios foram de 16,9 ± 0,7 mmHg e 17,9 ± 0,9 mmHg para esses mesmos grupos, respectivamente (p<0,0001). Ambos os grupos tiveram uma redução estatisticamente significativa da pressão intraocular em relação aos valores pré-operatórios (p<0,0001) em todos os momentos do acompanhamento. A taxa de sucesso não qualificado nos grupos da viscotrabeculotomia com irrigação da câmara anterior e do implante de válvula de Ahmed foi de 72,73% e 61,9%, respectivamente. A complicação mais comum foi o hifema, autolimitado e mínimo. Conclusões: Tanto a viscotrabeculotomia com irrigação da câmara anterior quanto o implante de válvula de Ahmed são eficazes na redução da pressão intraocular no glaucoma após injeção de óleo de silicone, mas a viscotrabeculotomia com irrigação em câmara anterior proporcionou maior redução da pressão intraocular e maiores taxas de sucesso, com complicações mínimas.

8.
Arq. bras. oftalmol ; 86(2): 121-126, Mar.-Apr. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1429840

ABSTRACT

ABSTRACT Purpose: To assess intraocular pressure and ocular pulse amplitude changes in obese children and adolescents using dynamic contour tonometry. Methods: 137 cases, 64 obese and 73 healthy children, who were both age-matched and gender-matched, comprised the study population in this cross-sectional study. Children with body mass index values >95% for sex and age were regarded as obese. Participants underwent detailed ophthalmological examinations, including intraocular pressure measurement using a Pascal dynamic contour tonometer. Relationships between intraocular pressure and ocular pulse amplitude measurements and age, sex, obesity, pubertal status, and insulin resistance were investigated. Results: Bilateral ocular pulse amplitude was lower while intraocular pressure was higher in the obese group than in the control group (p<0.001). No significant relationship was observed between insulin resistance and intraocular pressure or ocular pulse amplitude (p>0.005). No correlation was determined between systolic and diastolic blood pressure, homeostasis model assessment for insulin resistance, or blood lipid levels and intraocular pressure and ocular pulse amplitude. Conclusion: Our results show that obesity caused an increase in intraocular pressure and a decrease in ocular pulse amplitude independently of insulin resistance in children and adolescents. Prospective studies involving long-term follow-up of cases are now needed to assess the probable adverse effects of these ocular findings in obese children.


RESUMO Objetivo: Avaliar a pressão intraocular e as alterações da amplitude do pulso ocular em crianças e adolescentes obesos, usando tonometria de contorno dinâmico. Métodos: Um total de 137 casos, sendo 64 crianças obesas e 73 crianças saudáveis, pareadas por idade e sexo, compôs a população estudada neste estudo transversal. Crianças com valores de índice de massa corporal superior ao percentil de 95% para seu sexo e idade foram consideradas obesas. Os participantes foram submetidos a exames oftalmológicos detalhados, incluindo a medição da pressão intraocular com um tonômetro de contorno dinâmico Pascal. As relações entre a pressão intraocular e as medidas da amplitude do pulso ocular com a idade, sexo, obesidade, estado puberal e resistência à insulina foram investigadas. Resultados: A amplitude do pulso ocular bilateral foi menor no grupo obeso do que no grupo controle saudável (p<0,001), enquanto a pressão intraocular foi maior (p<0,001). Não foi observada nenhuma relação significativa entre a resistência à insulina e a pressão intraocular ou a amplitude de pulso ocular (p>0,005). Não foi determinada nenhuma correlação entre a pressão arterial sistólica e diastólica, a avaliação do modelo de homeostase para resistência à insulina ou os níveis de lipídios sanguíneos e a pressão intraocular e a amplitude de pulso ocular. Conclusão: Os resultados mostraram que a obesidade causou um aumento da pressão intraocular e uma diminuição da amplitude do pulso ocular em crianças e adolescentes, independentemente da resistência à insulina. São necessários agora estudos prospectivos envolvendo o seguimento de longo prazo dos casos, para avaliar os prováveis efeitos adversos desses achados oculares observados em crianças obesas.

9.
Arq. bras. oftalmol ; 86(2): 137-144, Mar.-Apr. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1429841

ABSTRACT

ABSTRACT Purpose: To describe the frequency, clinical characteristics, complications, and management of glaucoma in eyes that underwent keratoprosthesis implantation. Methods: Patients who underwent keratoprosthesis surgery between June 2010 and January 2020 were retrospectively evaluated for glaucoma association and prognoses. Results: Among 17 patients who underwent keratoprosthesis surgery, 9 (52.9%) were associated with underlying or keratoprosthesis-induced glaucoma. Five eyes (29.4%) had underlying glaucoma and underwent a glaucoma drainage device implantation at least 6 months before keratoprosthesis surgery. One eye (5.9%) with normal intraocular pressure had glaucoma drainage device implantation at the same session with keratoprosthesis surgery due to high-risk characteristics of anterior segment structures. Four eyes with preexisting glaucoma showed progression after keratoprosthesis surgery. Additional antiglaucomatous treatment was commenced in two eyes whereas implantation of 2nd glaucoma drainage device was performed in two eyes. Postoperative complications in three eyes (100%) with glaucoma drainage device implanted 6 months before or at the same session with aphakic type keratoprosthesis surgery with partial vitrectomy included rhegmatogenous retinal detachment in two eyes and bacterial endophthalmitis in one eye. Migration of silicone oil through the tube to the subconjunctival area was seen after pars plana vitrectomy in one eye. None of the three eyes (0%) that underwent glaucoma drainage device implantation years before keratoprosthesis surgery experienced a posterior segment complication other than glaucomatous progression. Out of 11 eyes with no previous history of glaucoma, 3 (27.3%) showed high intraocular pressure and glaucomatous disc changes after keratoprosthesis surgery, which could be pharmacologically controlled. Conclusions: In this cohort, eyes with preexisting glaucoma were more difficult to manage compared to eyes with de novo glaucoma after keratoprosthesis surgery. Retinal complications appeared more often when glaucoma drainage device implantation was performed no more than 6 months before aphakic type keratoprosthesis surgery with partial vitrectomy.


RESUMO Objetivo: Descrever a frequência, as características clínicas, as complicações e o manejo do glaucoma em olhos submetidos a implantes de ceratoprótese. Métodos: Pacientes submetidos à cirurgia de ceratoprótese entre junho de 2010 e janeiro de 2020 foram avaliados retrospectivamente em termos de glaucoma associado e prognóstico. Resultados: Dos 17 pacientes submetidos à cirurgia de ceratoprótese, em 9 (52,9%) foi constatado glaucoma subjacente ou induzido por ceratoprótese. Cinco olhos (29,4%) tinham glaucoma subjacente e receberam a implantação de um dispositivo de drenagem de glaucoma pelo menos 6 meses antes da cirurgia de ceratoprótese. Um olho (5,9%) com pressão intraocular normal teve implantado um dispositivo de drenagem de glaucoma na mesma sessão da cirurgia de ceratoprótese, devido às características de "alto risco" das estruturas do segmento anterior. Quatro dos olhos com glaucoma preexistente apresentaram progressão após a cirurgia de ceratoprótese. Foi iniciado um tratamento antiglaucomatoso adicional em 2 olhos, enquanto outros 2 olhos receberam o implante de um segundo dispositivo de drenagem de glaucoma. Foram observadas complicações pós-operatórias em 3 olhos (100%) com dispositivo de drenagem de glaucoma implantado 6 meses antes ou na mesma sessão da cirurgia de ceratoprótese tipo afácica com vitrectomia parcial, incluindo descolamento de retina regmatogênico em 2 olhos e endoftalmite bacteriana em 1 olho. Em 1 olho observou-se migração do óleo de silicone para a área subconjuntival através do tubo após vitrectomia via pars plana. Nenhum dos 3 olhos (0%) implantados com dispositivo de drenagem de glaucoma anos antes da cirurgia de ceratoprótese apresentou complicações do segmento posterior, exceto progressão glaucomatosa. Dos 11 olhos sem história prévia de glaucoma, 3 (27,3%) apresentaram alta pressão intraocular e alterações do disco glaucomatoso após cirurgia de ceratoprótese, condições que podem ser controladas clinicamente. Conclusões: Nesta coorte, os olhos com glaucoma pré-existente foram mais difíceis de manejar, comparados àqueles que desenvolveram glaucoma após a cirurgia de ceratoprótese. Apareceram mais complicações retinianas quando o implante do dispositivo de drenagem de glaucoma foi realizado no máximo 6 meses antes da cirurgia de ceratoprótese do tipo afácico com vitrectomia parcial.

10.
Arq. bras. oftalmol ; 86(5): e2021, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1513683

ABSTRACT

ABSTRACT We assessed the effects of anti-inflammatory treatment after selective laser trabeculoplasty through a systematic search of the MEDLINE, COCHRANE, and ClinicalTrials.gov. The outcome measures were intraocular pressure, anterior chamber inflammation, and discomfort. Evidence synthesis was performed using fixed effects or random-effects model according to the heterogeneity of the included studies. Heterogeneity was assessed using Q-statistic and I2. For an overall estimate of continuous outcomes, the mean differences and their 95% confidence intervals were applied, while odds ratios and their 95% confidence intervals were applied for dichotomous outcomes. Six studies were included in all. No significant difference was noted in the patients for intraocular pressure and discomfort when treated with anti-inflammatory drops. However, the patients showed benefit from reduced anterior chamber inflammation in the first postoperative week [FE OR=0.43, 95% CI=(0.19, 0.95), PQ=0.97, I2=0%], with no significant difference between the outcomes of non-steroidal anti-inflammatory drugs and steroids [FE OR=0.75, 95% CI=(0.20, 2.82), PQ=0.37, I2=0%]. Anti-inflammatory drops reduce anterior chamber inflammation after selective laser trabeculoplasty but showed no effect on the intraocular pressure.


RESUMO O objetivo deste estudo é avaliar os efeitos do tratamento anti-inflamatório após a trabeculoplastia seletiva a laser. Uma busca sistemática foi feita no MEDLINE, COCHRANE e ClinicalTrials.gov. As medidas de resultado foram pressão intraocular, inflamação da câmara anterior e desconforto. A síntese de evidência foi realizada utilizando-se modelo de efeitos fixos ou efeitos aleatórios, de acordo com a heterogeneidade dos estudos incluídos. A heterogeneidade foi avaliada utilizando-se Q-statistic e I². Para uma estimativa global dos resultados contínuos, foram usadas diferenças médias e seus intervalos de confiança de 95% enquanto para resultados dicótomos, usou-se odds ratios e seus intervalos de confiança de 95%. Seis estudos foram incluídos. Nenhuma diferença significativa foi encontrada em pacientes tratados com gotas anti-inflamatórias em termos de pressão intraocular e desconforto. No entanto, eles se beneficiaram da redução da inflamação da câmara anterior na primeira semana pós-operatória [FE OR=0,43, IC 95% = (0,19, 0,95), PQ=0,97, I2=0%], sem diferença significativa entre anti-inflamatórios não esteroidais e esteroidais [FE OR=0,75, IC 95% = (0,20, 2,82), PQ=0,37, I2=0%]. Gotas anti-inflamatórias reduzem a inflamação da câmara anterior após trabeculoplastia seletiva a laser, não afetando a pressão intraocular.

11.
Arq. bras. oftalmol ; 85(5): 490-497, Sept.-Oct. 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1403429

ABSTRACT

ABSTRACT Purpose: The objective of this study was to investigate the usefulness of four different algorithms to correct noncontact intraocular pressure measurement errors in keratoconus patients and normal individuals. Methods: Noncorrected intraocular pressure and corrected intraocular pressures were measured in one eye of 34 patients with keratoconus and 34 age- and gender-matched healthy controls using Corvis Scheimpflug Technology. The correlation of noncorrected intraocular pressure and corrected intraocular pressures with age, axial length, corneal shape, thickness, and biomechanics was calculated. Corrected intraocular pressures were compared with noncorrected intraocular pressure using paired t test and Bland-Altman plots (95% limits of agreement). Results: The noncorrected intraocular pressure correlated with corneal thickness and biomechanical parameters in both groups (all p≤0.047), and front and back mean keratometry in the keratoconus group (r=-0.39, p=0.02, and r=0.39, p=0.02, respectively). After adjustment with different intraocular pressure correction algorithms, biomechanically corrected intraocular pressure showed a minimal correlation with corneal features and a nonsignificant difference with noncorrected intraocular pressure in the healthy group (-0.1 ± 1.1 mmHg, p=0.58; 95% limits of agreement: -2.3 to 2.1 mmHg). Conclusions: Measuring intraocular pressure using noncontact tonometry and its corrected forms with a corneal thickness-based simple linear formula in patients with keratoconus is associated with many errors. Using more complex formulas that take into consideration more corneal stiffness parameters in addition to corneal thickness, such as biomechanically corrected intraocular pressure formula, may be more reliable and beneficial in this group of patients.


RESUMO Objetivo: Investigar a utilidade de quatro algoritmos diferentes para corrigir erros de medição sem contato da pressão intraocular em pacientes saudáveis e com ceratocone. Métodos: A pressão intraocular não corrigida e as pressões intraoculares corrigidas foram medidas em um olho de 34 pacientes com ceratocone e 34 pacientes do grupo controle saudável pareados por idade e gênero usando a tecnologia Corvis Scheimpflug. Foi calculada a correlação da pressão intraocular não corrigida e das pressões intraoculares corrigidas com idade, comprimento axial e formato, espessura e biomecânica da córnea. As pressões intraoculares corrigidas foram comparadas com a pressão intraocular não corrigida usando o teste t pareado, e gráficos de Bland-Altman (limites de concordância de 95%). Resultados: A pressão intraocular não corrigida correlacionou-se com a espessura da córnea e com os parâmetros biomecânicos em ambos os grupos (todos p≤0,047) e a ceratometria média frontal e posterior no grupo com ceratocone (r=-0,39, p=0,02, r=0,39, p=0,02, respectivamente). Após o ajuste com diferentes algoritmos de correção da pressão intraocular, a pressão intraocular corrigida biomecanicamente revelou uma correlação mínima com as características da córnea e uma diferença não significativa com a pressão intraocular não corrigida no grupo saudável (-0,1 ± 1,1 mmHg, p=0,58; limites de concordância de 95%: -2,3 a 2,1 mmHg). Conclusões: A medição da pressão intraocular usando tonometria sem contato e suas formas corrigidas usando fórmulas lineares, simples, baseadas na espessura da córnea em pacientes com ceratocone estão associadas a muitos erros. O uso de fórmulas mais complexas que consideram mais parâmetros de rigidez da córnea além da espessura da córnea, como fórmula de pressão intraocular corrigida biomecanicamente, pode ser mais confiável e benéfico neste grupo de pacientes.

12.
Arq. bras. oftalmol ; 85(5): 478-484, Sept.-Oct. 2022. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1403436

ABSTRACT

ABSTRACT Purpose: To examine the effect of subepithelial corneal infiltrates on corneal biomechanical properties after epidemic keratoconjunctivitis compared to that in healthy controls. Methods: The cross-sectional study included consecutive patients with bilateral subepithelial corneal infiltrates after epidemic keratoconjunctivitis and healthy controls. Best corrected visual acuity corneal subepithelial infiltrate scoring Fantes grading scale, and central corneal thickness were measured. Corneal hysteresis corneal resistance factor Goldmann correlated intraocular pressure and corneal compensated intraocular pressure were assessed using an ocular response analyzer. Results: This study included 66 eyes of 33 patients with subepithelial corneal infiltrates following epidemic keratoconjunctivitis and randomly selected 37 eyes of 37 healthy volunteers. The mean Fantes and CSIS scores were 1.8 ± 0.8 and 2.9 ± 1.3, respectively, in the first involved eyes and 1.3 ± 1.1 and 1.9 ± 1.7, respectively, in the fellow eyes (p=0.009 and p=0.002, respectively). The first (526.1 ± 28.1 µm; p=0.005) and second involved eyes (523.4 ± 38.1 µm; p=0.044) had significantly thinner corneas compared to that in healthy controls (557.0 ± 38.1 µm). While best-corrected visual acuity showed a positive correlation with corneal resistance factor (r=0.363, p=0.045) and corneal hysteresis (r=0.414, p=0.021), corneal subepithelial infiltrate scoring showed a negative correlation with Goldmann correlated intraocular pressure (r=-0.479, p=0.006) and corneal compensated intraocular pressure (r=-0.413, p=0.021). Conclusion: Eyes with subepithelial corneal infiltrates had significantly thinner corneas compared to that in healthy controls. A positive correlation of the corneal resistance factor and corneal hysteresis with best-corrected visual acuity and a negative correlation of the Goldmann correlated intraocular pressure and corneal compensated intraocular pressure with corneal subepithelial infiltrate scoring should be taken into account when measuring intraocular pressure values in patients with subepithelial corneal infiltrates.


RESUMO Objetivo: Examinar o efeito de infiltrados sub-epiteliais corneanos nas propriedades biomecânicas da córnea após ceratoconjuntivite epidêmica, em comparação com controles saudáveis. Métodos: Este estudo transversal incluiu pacientes consecutivos com infiltrados sub-epiteliais corneanos bilaterais após ceratoconjuntivite epidêmica e controles saudáveis. Foram medidas a melhor acuidade visual corrigida, uma pontuação do infiltrado sub-epitelial da córnea, a escala de graduação de Fantes e a espessura central da córnea. A histerese da córnea, o fator de resistência da córnea, a pressão intraocular correlacionada à tonometria de Goldmann e a pressão intraocular compensada da córnea foram avaliados com o Ocular Response Analyzer. Resultados: Este estudo incluiu 66 olhos de 33 pacientes com infiltrados corneanos sub-epiteliais após ceratoconjuntivite epidêmica e selecionou aleatoriamente 37 olhos de 37 voluntários saudáveis. As pontuações médias da escala de Fantes e dos infiltrados sub-epiteliais corneanos nos primeiros olhos acometidos foram respectivamente de 1,8 ± 0,8 e 2,9 ± 1,3. Nos olhos contralaterais, foram respectivamente de 1,3 ± 1,1 e 1,9 ± 1,7 (p=0,009 e p=0,002, respectivamente). O primeiro e o segundo olhos envolvidos tinham córneas significativamente mais finas (respectivamente 526,1 ± 28,1 µm; p=0,005 e 523,4 ± 38,1 µm; p=0,044) em comparação com os controles saudáveis (557,0 ± 38,1 µm). Embora a acuidade visual melhor corrigida tenha mostrado uma correlação positiva com o fator de resistência da córnea (r=0,363, p=0,045) e com a histerese da córnea (r=0,414, p=0,021), a pontuação dos infiltrados sub-epiteliais corneanos mostrou uma correlação negativa com a pressão intraocular correlacionada à tonometria de Goldmann (r=-0,479, p=0,006) e com a pressão intraocular compensada da córnea (r=-0,413, p=0,021). Conclusão: Os olhos com infiltrados corneanos sub-epiteliais tinham córneas significativamente mais finas em comparação com os controles saudáveis. Ao se medirem os valores de pressão intraocular em pacientes com infiltrados sub-epiteliais corneanos, deve-se levar em consideração tanto as correlações positivas do fator de resistência da córnea e da histerese da córnea com a melhor acuidade visual corrigida quanto as correlações negativas da pressão intraocular correlacionada à tonometria de Goldmann e da pressão intraocular compensada da córnea com a pontuação do infiltrado sub-epitelial da córnea.

13.
Arq. bras. oftalmol ; 85(5): 485-489, Sept.-Oct. 2022. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1403445

ABSTRACT

ABSTRACT Purpose: To evaluate the effect of pupil dilation on intraocular pressure in preterm and term newborns. Methods: This prospective study involved 55 eyes of 28 preterm infants and 38 eyes of 20 term infants. The infants were divided into two groups according to their gestational ages at birth as follows: preterm group, <37 weeks and term group, ≥37 weeks. Pupil dilation was attained with tropicamide 0.5% and phenylephrine 2.5%. Intraocular pressure measurements were performed with Icare PRO (Icare Finland Oy, Helsinki, Finland) before and after pupil dilation. A paired t test was used to compare the measurements before and after pupil dilation. Results: The mean intraocular pressure change was -1.04 ± 3.03 mmHg (6.20/-11.40 mmHg) in the preterm group and -0.39 ± 2.81 mmHg (4.60/-9.70 mmHg) in the term group. A statistically significant difference in intraocular pressure was observed only in the preterm group after pupil dilation (p=0.01). Conclusion: An unexpected alteration in intraocular pressure in newborns may occur after pupil dilation, especially in preterm infants.


RESUMO Objetivo: Avaliar o efeito da dilatação da pupila sobre a pressão intraocular em recém-nascidos pré-termo e a termo. Métodos: Este estudo prospectivo envolveu 55 olhos de 28 bebês pré-termo e 38 olhos de 20 bebês a termo. Os bebês foram divididos em dois grupos, pré-termo e a termo, de acordo com a idade gestacional ao nascimento: grupo pré-termo <37 semanas; grupo a termo ≥37 semanas. A dilatação da pupila foi feita com tropicamida 0,5% e fenilefrina 2,5%. As medições da pressão intraocular foram realizadas com Icare PRO (Icare Finland Oy, Helsinki, Finlândia) antes e depois da dilatação da pupila. O teste t pareado foi usado para comparar as medidas antes e depois da dilatação da pupila. Resultados: A alteração média da pressão intraocular foi de -1,04 ± 3,03 mmHg (+6,20/-11,40 mmHg) no grupo pré-termo e -0,39 ± 2,81 mmHg (+4,60/-9,70 mmHg) no grupo a termo. Uma diferença estatisticamente significativa na pressão intraocular foi observada apenas no grupo pré-termo após a dilatação da pupila (p=0,01). Conclusão: Após a dilatação da pupila, pode ocorrer alteração inesperada da pressão intraocular em recém-nascidos, principalmente em bebês pré-termo.

14.
Arq. bras. oftalmol ; 85(4): 359-363, July-Aug. 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1383826

ABSTRACT

ABSTRACT Purpose: The purpose of this study was to investigate the postoperative outcomes and evaluate the success predictors of phacoemulsification with Kahook Dual Blade goniotomy for cataract and glaucoma management in eyes with primary open-angle glaucoma. Methods: This was a retrospective, non-comparative; inter ventional case series in which all patients with primary open-angle glaucoma who underwent phacoemulsification with Kahook Dual Blade goniotomy between June 2018 and April 2019 were enrolled. All the participants had a minimum follow-up period of 6 months. Preoperative and postoperative intraocular pressure values (at 1, 3, and 6 months), number of antiglaucoma medications, best-corrected visual acuity, surgical complications, and any subsequent related events or procedures were recorded. A logistic regression analysis was performed to investigate the association between the different variables and surgical outcomes. Results: A total of 47 patients (57 eyes) were included (mean age, 70.5 ± 7 years). The mean intraocular pressure was reduced from 15.5 ± 4.2 mmHg to 12.2 ± 2.4 mmHg at the last follow-up visit (p<0.001). The mean number of antiglaucoma medications decreased significantly from 1.9 ± 1.0 to 0.6 ± 1.0 during the same period (p<0.001). On the basis of the predefined criterion (intraocular pressure reduction ≥20% and/or reduction ≥1 medication), the 6-month success rate was 86%. A higher preoperative intraocular pressure value (odds ratio [OR]= 2.01; p=0.016) and greater percentage of initial (30 days) intraocular pressure reduction (OR= 1.02; p=0.033) were sig nificantly associated with surgical success. Conclusion: Our findings suggest that phacoemulsification with Kahook Dual Blade goniotomy is an effective and safe alternative for cataract management in eyes with primary open-angle glaucoma that positively impacts intraocular pressure control and medication burden. Eyes with higher baseline intraocular pressure and a more pronounced initial response to the procedure appeared to present better outcomes at 6 months. Further studies are needed to evaluate the long-term efficacy and safety profile of the procedure.


RESUMO Objetivo: Investigar os resultados pós-operatórios e avaliar os preditores de sucesso da facoemulsificação combinada à goniotomia com o Kahook Dual Blade para o tratamento da catarata e do glaucoma em olhos com glaucoma primário de ângulo aberto. Métodos: Série de casos retrospectivos, não comparativos e intervencionistas, em que todos os pacientes com glaucoma primário de ângulo aberto submetidos ao procedimento de facoemulsificação combinada à goniotomia com o Kahook Dual Blade entre junho de 2018 e abril de 2019 foram inscritos. Todos os participantes tiveram um acompanhamento mínimo de 6 meses. Foram registrados os valores de pressão intraocular pré e pós-operatória (em 1, 3 e 6 meses), número de medicamentos antiglaucomatosos, melhor acuidade visual corrigida, complicações cirúrgicas e quaisquer eventos ou procedimentos subsequentes relacionados. A análise de regressão logística foi usada para investigar a associação entre diferentes variáveis e resultados cirúrgicos. Resultados: Um total de 57 olhos de 47 pacientes foram incluídos (média de idade, 70,5 ± 7 anos). A pressão intraocular média reduziu de 15,5 ± 4,2 mmHg para 12,2 ± 2,4 mmHg na última visita de acompanhamento (p<0,001). O número médio de medicamentos antiglaucomatosos diminuiu significativamente de 1,9 ± 1,0 para 0,6 ± 1,0 durante o mesmo período (p<0,001). Com base no critério predefinido (redução da pressão intraocular ≥20% e/ou redução de ≥1 medicamento), a taxa de sucesso em 6 meses foi de 86%. Um valor de pressão intraocular pré-operatório mais alto (OR= 2,01; p=0,016) e maior porcentagem de redução da pressão intraocular inicial (30 dias) (OR= 1,02; p=0,033) foram significativamente associados ao sucesso cirúrgico. Conclusão: Nossos resultados sugerem que o procedimento de facoemulsificação combinada à goniotomia com o Kahook Dual Blade é uma alternativa eficaz e segura para o manejo da catarata em olhos com glaucoma primário de ângulo aberto, impactando positivamente no controle da pressão intraocular e no número de medicamentos. Olhos com pressão intraocular basal mais alta e resposta inicial mais pronunciada ao procedimento parecem apresentar melhores resultados em 6 meses. Mais estudos são necessários para avaliar a eficácia em longo prazo e o perfil de segurança.

15.
Belo Horizonte; s.n; 2022. 97 p.
Thesis in Portuguese | LILACS, InstitutionalDB, ColecionaSUS | ID: biblio-1435278

ABSTRACT

Introdução: Glaucoma é uma neuropatia óptica caracterizada pela perda irreversível das células ganglionares retinianas, sendo a pressão intraocular (Po) o principal fator de risco para a doença. Grandes variações da pressão intraocular durante um determinado período de tempo têm atraído a atenção como um potencial fator de risco para o desenvolvimento e progressão do glaucoma. Objetivo: Avaliar a relação entre a flutuação de 24 horas da pressão intraocular (∆Po) e a espessura da camada de fibras nervosas da retina (CFNR) medida por tomografia de coerência óptica de domínio espectral (TCO-DE). Método: O estudo incluiu 125 olhos de 65 pacientes. Sessenta e três olhos (50,4%) tiveram o diagnóstico de glaucoma primário de ângulo aberto (GPAA) e 62 (49,6%) foram considerados suspeitos de glaucoma (SG). Todos os olhos foram submetidos a imagens usando TCO-DE, juntamente com medição da Po de 24 horas e perimetria computadorizada acromática. Apenas pacientes com ∆Po anormal (>6 mmHg) foram incluídos. Correlação e modelos mistos lineares generalizados foram usados para investigar a relação entre ∆Po e a espessura da CFNR ajustando para potenciais fatores de confusão, como idade, diagnóstico de glaucoma, espessura da córnea, Po média durante 24 horas e gravidade da doença. Resultados: A idade média foi semelhante entre os grupos SG e GPAA (62,2 ± 15,6 vs. 64,6 ± 12,0, P = 0,50), enquanto o desvio médio do campo visual apresentou diferença entre SG e GPAA (0,41 ± 1,33 vs. -3,09 ± 3,23, P <0,001). A Po média também foi semelhante entre os grupos SG e GPAA (15,6 ± 3,47 vs. 15,6 ± 2,83 mmHg, P = 0,90), assim como o pico da Po às 6h (21,7 ± 3,85 vs. 21,3 ± 3,80 mmHg, P = 0,68). Correlações negativas estatisticamente significativas foram encontradas no grupo GPAA entre a Po às 6h e a espessura da CFNR global (rs = 0,543; P < 0,001), quadrantes inferior (rs = -0,540; P < 0,001), superior (rs = -0,405; P = 0,009) e nasal (rs = −0,561; P < 0,001). Correlações negativas também foram encontradas entre ∆Po e a espessura da CFNR global (rs = −0,591; P < 0,001), e todos os demais setores (P < 0,05). No SG a Po às 6h correlacionou-se apenas com a espessura da CFNR no quadrante inferior (rs = −0,307; P = 0,047). Cada 1 mmHg maior na ∆Po foi associado à afilamento de -1,44 µm na espessura global da CFNR (IC 95%: -2,77 a -0,11, P = 0,03). Além disso, cada incremento de 10 anos na idade foi associado à afilamento de -3,56 µm na espessura global da CFNR (IC 95%: -6,06 a -1,05, P = 0,006). O GPAA teve uma afilamento média de -10,91 µm na CFNR global em relação aos SG (IC 95%: -20,21 a -1,62, P = 0,02). A Po média não foi associada à espessura global da CFNR (IC 95%: -1,37 a 0,91, P = 0,69). Conclusão: Maior ∆Po foi associado à menor espessura global da CFNR medida pelo TCO-DE, em pacientes com ∆Po >6 mmHg. Esse achado corrobora um papel potencial da flutuação da Po como fator de risco para perda estrutural no glaucoma.


Introduction: Glaucoma is an optic neuropathy characterized by irreversible loss of retinal ganglion cells, with intraocular pressure (IOP) being the main risk factor for the disease. Large variations in IOP over a period of time have attracted attention as a potential risk factor for the development and progression of glaucoma. Purpose: To evaluate the relationship between 24-hour fluctuation of intraocular pressure (∆IOP) and retinal nerve fiber layer (RNFL) thickness measured by spectraldomain optical coherence tomography (SD-OCT). Material and Methods: The study included 125 eyes of 65 patients. Sixty-three eyes (50.4%) had a diagnosis of primary open angle glaucoma (POAG) and 62 (49.6%) were considered glaucoma suspects (GS). All eyes underwent imaging using SDOCT, along with 24-hour IOP measurement and standard automated perimetry. Only patients with abnormal ∆IOP (>6 mmHg) were included. Correlation and generalized linear mixed models were used to investigate the relationship between ∆IOP and RNFL thickness adjusting for potential confounding factors such as age, glaucoma diagnosis, corneal thickness, mean IOP during 24 hours, and disease severity. Results: Mean age was similar between the SG and POAG groups (62.2 ± 15.6 vs. 64.6 ± 12.0, P = 0.50), while the mean deviation of visual field showed a difference between SG and POAG (0.41 ± 1.33 vs. -3.09 ± 3.23, P < 0.001). The mean Po was also similar between GS and POAG groups (15.6 ± 3.47 vs 15.6 ± 2.83 mmHg, P = 0.90) as was IOP peak at 6 AM (21.7 ± 3.85 vs. 21.3 ± 3.80 mmHg, P = 0.68). Statistically significant negative correlations were found in POAG group between IOP at 6 AM and RNFL thickness in global (rs = −0.543; P < 0.001), inferior (rs = −0.540; P < 0.001), superior (rs = −0.405; P = 0.009), and nasal quadrants (rs = −0.561; P < 0.001). Negative correlations were also found between ∆IOP and RNFL thickness in global (rs = −0.591; P < 0.001), and all other sectors (P < 0.05). In GS IOP at 6 AM correlated only with RNFL thickness in the inferior quadrant (rs = −0.307; P = 0.047). Each 1 mmHg higher in ∆IOP was associated with thinning of -1.44 µm in global RNFL thickness (95% CI: -2.77 to -0.11, P = 0.03). Also, each 10-years increment in age was associated with thinning of -3.56 µm in global RNFL thickness (95% CI: 6.06 to -1.05, P = 0.006). POAG had on average -10.91 µm thinning in global RNFL than glaucoma suspects (95% CI: -20.21 to -1.62, P = 0.02). Mean IOP was not associated with global RNFL thickness (95% CI: -1.37 to 0.91, P = 0.69). Conclusion: Higher ∆IOP was associated with lower global RNFL thickness measured by SD-OCT, in patients with ∆IOP > 6 mmHg. This finding corroborates a potential role for IOP fluctuation as a risk factor for structural loss in glaucoma.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Optic Nerve , Diagnostic Imaging , Glaucoma, Open-Angle , Ocular Hypertension , Intraocular Pressure
16.
Rev. bras. oftalmol ; 81: e0041, 2022. tab, graf
Article in English | LILACS | ID: biblio-1387975

ABSTRACT

ABSTRACT Glaucoma drainage devices are important therapeutic options for cases of refractory glaucoma, in which trabeculectomy with antimetabolites has shown high risk of failure. There are devices with different sizes, designs and materials, and several studies have been conducted to test their safety and effectiveness. Despite known complications, their use has progressively increased in recent years, and they are the primary surgical option, in some situations. The aim of this review is to discuss the importance, mechanisms, biomaterials, results and complications of glaucoma drainage devices.


RESUMO Os dispositivos de drenagem para glaucoma são importante opção terapêutica em casos de glaucomas refratários, nos quais a trabeculectomia com antimetabólitos tem alta chance de falência. Há dispositivos com diferentes tamanhos, desenhos e materiais, e muitos estudos foram realizados para testar sua segurança e eficácia. Apesar de suas conhecidas complicações, seu uso tem aumentado progressivamente nos últimos anos, inclusive como primeira opção cirúrgica, em algumas situações. O objetivo desta revisão foi discutir a importância, os mecanismos, os biomateriais, os resultados e as complicações dos dispositivos de drenagem para glaucoma.


Subject(s)
Humans , Glaucoma/surgery , Filtering Surgery/instrumentation , Glaucoma Drainage Implants , Biocompatible Materials , Glaucoma/physiopathology , Filtering Surgery/methods , Prosthesis Implantation , Intraocular Pressure/physiology
17.
Rev. bras. oftalmol ; 81: e0036, 2022. tab, graf
Article in English | LILACS | ID: biblio-1376779

ABSTRACT

ABSTRACT The purpose of this study was to highlight the impact of biomechanical corneal response in available in vivo tonometry methods for glaucoma management. Systematic review of non-contact air-puff tonometers that analyzes the corneal deformation response, with special focus on the investigation of the correlation of derived parameters with intraocular pressure measurements. The two actual and commercially available in vivo corneal tonometers provide promising information about biomechanical characteristics of the cornea and its relation to glaucoma, allowing the development of new protocols to evaluate, diagnose, and manage this disease.


RESUMO O objetivo deste estudo é destacar o impacto da resposta biomecânica corneana em métodos de tonometria in vivo disponíveis para o manejo do glaucoma. Trata-se de revisão sistemática de tonômetros de ar que analisa a resposta à deformação corneana, com foco especial na investigação da correlação dos parâmetros derivados com as medições da pressão intraocular. Os dois tonômetros mais recentes e comercialmente disponíveis fornecem informações promissoras sobre as características biomecânicas da córnea e sua relação com o glaucoma, permitindo o desenvolvimento de novos protocolos para avaliar, diagnosticar e controlar a doença.


Subject(s)
Humans , Tonometry, Ocular/instrumentation , Tonometry, Ocular/methods , Biomechanical Phenomena , Cornea/anatomy & histology , Cornea/physiology , Intraocular Pressure/physiology , Glaucoma/physiopathology , Ocular Hypertension/physiopathology , Diagnostic Techniques, Ophthalmological/instrumentation , Elasticity/physiology , Models, Theoretical
18.
Rev. bras. oftalmol ; 81: e0102, 2022. tab, graf
Article in English | LILACS | ID: biblio-1407671

ABSTRACT

ABSTRACT The rate of visual field progression is an essential factor in determining risk of visual disability or blindness in glaucoma patients. Knowledge of the rate of progression of a particular patient, in combination with an estimation of their longevity and other clinical factors, allows clinicians to optimize management by providing appropriately aggressive treatment. Despite decades of research on the treatment of glaucoma, the natural history of glaucomatous visual field progression in untreated and treated patients remains unclear. The purpose of this review is to provide a comprehensive summary of the literature surrounding the rate of visual field progression in glaucoma. Most of the available data pertains to primary open angle glaucoma, but we will also review progression rates in other subtypes of open angle glaucoma, such as pseudoexfoliative glaucoma and normal tension glaucoma, as well as in primary angle closure glaucoma. Specifically, we will cover methods to identify rates of progression, rates of progression in treated versus untreated patients, factors that may influence progression, and lastly, suggest some parameters that might help clinicians in determining acceptable rates of visual field deterioration in patients with glaucoma.


RESUMO A taxa de progressão do campo visual é um fator essencial para determinar o risco de incapacidade visual ou cegueira em pacientes com glaucoma. Conhecer a taxa de progressão de um determinado paciente, em combinação com uma estimativa de sua longevidade e outros fatores clínicos, permite que os médicos otimizem a conduta, fornecendo um tratamento adequadamente agressivo. Apesar de décadas de pesquisa sobre o tratamento do glaucoma, a história natural da progressão do campo visual glaucomatoso em pacientes não tratados e tratados permanece pouco clara. O objetivo desta revisão é fornecer um resumo abrangente da literatura sobre a taxa de progressão do campo visual do glaucoma. A maioria dos dados disponíveis diz respeito ao glaucoma de ângulo aberto primário, mas também revisaremos as taxas de progressão em outros subtipos de glaucoma de ângulo aberto, como o glaucoma pseudoexfoliativo e o glaucoma de tensão normal, bem como o glaucoma primário de ângulo fechado. Especificamente, iremos cobrir métodos para identificar taxas de progressão, taxas de progressão em pacientes tratados versus não tratados, fatores que podem influenciar a progressão e, finalmente, sugerir alguns parâmetros que podem ajudar os médicos a determinar taxas aceitáveis de deterioração do campo visual em pacientes com glaucoma


Subject(s)
Humans , Visual Fields , Glaucoma/complications , Glaucoma/diagnosis , Linear Models , Glaucoma/physiopathology , Blindness/etiology , Risk Factors , Disease Progression , Visual Field Tests/methods , Intraocular Pressure
19.
Rev. bras. oftalmol ; 81: e0002, 2022. tab, graf
Article in Portuguese | LILACS | ID: biblio-1357126

ABSTRACT

RESUMO Objetivo Avaliar a eficácia da trabeculotomia transluminal assistida por gonioscopia correlacionada com a gravidade do glaucoma. Métodos Análise restrospectiva de prontuários de pacientes que foram submetidos à trabeculotomia transluminal assistida por gonioscopia no período de 2019 a 2021 em um hospital privado. Resultados Vinte olhos foram submetidos à trabeculotomia transluminal assistida por gonioscopia (dois olhos) ou facectomia e trabeculotomia transluminal assistida por gonioscopia (18 olhos). Pacientes portadores da doença avançada obtiveram redução de 5mmHg (26,5%) na pressão intraocular, com redução de 2,3 drogas, e olhos com glaucoma leve ou moderado apresentaram redução de 8mmHg (40%) na pressão intraocular média e 2,1 drogas. Metade dos olhos operados teve hifema nos primeiros dias como principal complicação cirúrgica. Conclusão A trabeculotomia transluminal assistida por gonioscopia é um procedimento eficaz na redução da pressão intraocular e na redução da quantidade de drogas em uso, apresentando maior redução da pressão intraocular em olhos com glaucoma leve/moderado.


ABSTRACT Objective To evaluate efficacy of gonioscopy-assisted transluminal trabeculotomy and relate to severity of glaucoma. Methods A retrospective analysis of medical records of patients submitted to gonioscopy-assisted transluminal trabeculotomy, at a private hospital, from 2019 to 2021. Results A total of 20 were submitted to gonioscopy-assisted transluminal trabeculotomy (2 eyes) or facectomy and gonioscopy-assisted transluminal trabeculotomy (18 eyes). Patients with advanced-stage disease achieved a decrease by 5 mmHg (26.5%) in IOP, with a reduction of 2.3 drugs, and eyes with mild or moderate glaucoma showed a drop by 8 mmHg (40%) in mean IOP and of 2.1 drugs. Half of the operated eyes had hyphema in the first days as the main surgical complication. Conclusion Gonioscopy-assisted transluminal trabeculotomy is an effective procedure to reduce IOP and the number of drugs being used, with greater IOP decrease in eyes with mild/moderate glaucoma.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Trabeculectomy , Glaucoma, Open-Angle/surgery , Glaucoma, Open-Angle/diagnosis , Medical Records , Retrospective Studies , Treatment Outcome , Gonioscopy/methods , Intraocular Pressure
20.
Ces med. vet. zootec ; 16(3): 10-27, sep.-dic. 2021. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1374892

ABSTRACT

Abstract Rabbits have played an important role in ophthalmological research processes, however in the environment there has been a deficiency of sensitive equipment in measurement of intraocular pressure for this species. To compare intraocular pressure (IOP) measured with rebound (TONOVET Plus®) and applanation (TONO-PEN VET®) tonometry in healthy New Zealand rabbits treated with Amlodipine. Twelve healthy male New Zealand white rabbits, 5 months old; two groups with 6 individuals were used in this study. The experimental group was given Amlodipine® at a dose of 5 mg/kg, once a day for a month. Blood pressure and intraocular pressure were measurement before treatment and 6 h after treatment in a period of one month. A trend is noted where the group of animals treated with amlodipine® presents lower values than the control group, both in systolic and diastolic pressure. The systolic pressure of the control group showed an average of 116.5 ± 7.9 mmHg and 117.4 ± 8.9 mmHg and the treatment group showed an average of 113.6 ± 7.9 mmHg and 111.8 ± 10.0 mmHg (pretreatment and posttreatment respectively). Tonometry: the values obtained using the TONOVET Plus® (19 ± 3 mmHg) are on average higher than the values obtained using the TONO-PEN VET® (17 ± 3 mmHg). It was possible to demonstrate the relationship between systemic blood pressure and intraocular pressure in New Zealand white rabbits. Rebound tonometry showed less variability in results than applanation tonometry. This study confirmed that both tonometers are reliable for measuring IOP in rabbits.


Resumen Los conejos han jugado un papel importante en los procesos de investigación oftalmológica, sin embargo, en el medio ha existido una deficiencia de equipos sensibles en la medición de la presión intraocular para esta especie. Para comparar la presión intraocular (PIO) medida con la tonometría de rebote (TONOVET Plus®) y aplanación (TONO-PEN VET®) en conejos Nueva Zelanda sanos y tratados con Amlodipino, fueron usados doce conejos Nueva Zelanda, machos, sanos, de 5 meses de edad y distribuidos en dos grupos con 6 individuos cada uno. El grupo experimental recibió Amlodipino® en una dosis de 5 mg/kg, una vez al día durante un mes. La presión arterial y la presión intraocular se midieron antes del tratamiento y 6 h después del tratamiento en un período de un mes. Se observa una tendencia donde el grupo de animales tratados con amlodipino® presenta valores más bajos que el grupo control, tanto en presión sistólica como diastólica. La presión sistólica del grupo control mostró un promedio de 116,5 ± 7,9 mmHg y 117,4 ± 8,9 mmHg y el grupo de tratamiento mostró un promedio de 113,6 ± 7,9 mmHg y 111,8 ± 10,0 mmHg (pretratamiento y postratamiento respectivamente). Tonometría: los valores obtenidos con el TONOVET Plus® (19 ± 3 mmHg) son en promedio superiores a los valores obtenidos con el TONO-PEN VET® (17 ± 3 mmHg). Fue posible demostrar la relación entre la presión arterial sistémica y la presión intraocular en conejos blancos Nueva Zelanda. La tonometría de rebote mostró menos variabilidad en los resultados que la tonometría de aplanamiento. Este estudio confirmó que ambos tonómetros son confiables para medir la PIO en conejos.


Resumo Os coelhos têm desempenhado um papel importante nos processos de pesquisa oftalmológica, porém no meio tem havido uma deficiência de equipamentos sensíveis na medida da pressão intraocular para esta espécie. Comparar a pressão intraocular (PIO) medida com tonometria de rebote (TONOVET Plus®) e de aplanação (TONO-PEN VET®) em coelhos saudáveis da Nova Zelândia tratados com Amlodipina®. Foram utilizados neste estudo doze coelhos brancos da Nova Zelândia, machos saudáveis, 5 meses de idade; distribuído em dois grupos com 6 indivíduos cada um. O grupo experimental recebeu Amlodipina® na dose de 5 mg / kg, uma vez ao dia durante um mês. A pressão arterial e a pressão intraocular foram medidas antes do tratamento e 6 horas após o tratamento em um período de um mês. Nota-se uma tendência onde o grupo de animais tratados com amlodipina® apresenta valores inferiores ao grupo controle, tanto na pressão sistólica quanto na diastólica. A pressão sistólica do grupo controle apresentou média de 116,5 ± 7,9 mmHg e 117,4 ± 8,9 mmHg e o grupo tratamento apresentou média de 113,6 ± 7,9 mmHg e 111,8 ± 10,0 mmHg (pré-tratamento e pós-tratamento, respectivamente). Tonometria: os valores obtidos com o TONOVET Plus® (19 ± 3 mmHg) são em média superiores aos valores obtidos com o TONO-PEN VET® (17 ± 3 mmHg). Foi possível demonstrar a relação entre a pressão arterial sistêmica e a pressão intraocular em coelhos brancos da Nova Zelândia. A tonometria de rebote mostrou menos variabilidade nos resultados do que a tonometria de aplanação. Este estudo confirmou que ambos os tonômetros são confiáveis para medir a PIO em coelhos.

SELECTION OF CITATIONS
SEARCH DETAIL